Review



interference screw 7- × 20-mm biosure regenesorb  (Biosure Inc)

 
  • Logo
  • About
  • News
  • Press Release
  • Team
  • Advisors
  • Partners
  • Contact
  • Bioz Stars
  • Bioz vStars
  • 90

    Structured Review

    Biosure Inc interference screw 7- × 20-mm biosure regenesorb
    Interference Screw 7 × 20 Mm Biosure Regenesorb, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/interference+screw+7++%C3%97+20+mm+biosure+regenesorb/pmc12255458-86-16-16
    Average 90 stars, based on 1 article reviews
    interference screw 7- × 20-mm biosure regenesorb - by Bioz Stars, 2026-10
    90/100 stars

    Images

    Related Articles

    other:

    Article Title: Can tape–screw fixation of a quadrupled semitendinosus graft in a full-length tibial tunnel provide superior fixation compared with a doubled semitendinosus–gracilis held with an interference screw? A matched-pair cadaveric biomechanical comparison
    Article Snippet: The Biosure screw has a flat head, is slightly conical, and incorporates a consistent wall thickness throughout the length of the screw with a tapered body for easier insertion [ ].



    Similar Products

    90
    Biosure Inc interference screw 7- × 20-mm biosure regenesorb
    Interference Screw 7 × 20 Mm Biosure Regenesorb, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/interference+screw+7++%C3%97+20+mm+biosure+regenesorb/pmc12255458-86-16-16
    Average 90 stars, based on 1 article reviews
    interference screw 7- × 20-mm biosure regenesorb - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc interference screw biosure
    Interference Screw Biosure, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/interference+screw+biosure/pm40210165-188-14-14
    Average 90 stars, based on 1 article reviews
    interference screw biosure - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc bio-composite interference screw biosure regenesorb
    Bio Composite Interference Screw Biosure Regenesorb, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/bio+composite+interference+screw+biosure+regenesorb/pmc11981489-77-6-9
    Average 90 stars, based on 1 article reviews
    bio-composite interference screw biosure regenesorb - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc biosure regenesorb screw
    The Biosure <t>Regenesorb</t> interference screw with its fenestrated design provides circumferential communication with the tibial tunnel and is composed of an absorbable material consisting of a combination of calcium sulphate (20%), b‐TCP(15%) and PLGA (65%).
    Biosure Regenesorb Screw, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/biosure+pk+screw/pmc11491983-152-8-8
    Average 90 stars, based on 1 article reviews
    biosure regenesorb screw - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc hounsfield unit threshold for the biosure regenesorb screw material
    The Biosure <t>Regenesorb</t> interference screw with its fenestrated design provides circumferential communication with the tibial tunnel and is composed of an absorbable material consisting of a combination of calcium sulphate (20%), b‐TCP(15%) and PLGA (65%).
    Hounsfield Unit Threshold For The Biosure Regenesorb Screw Material, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/hounsfield+unit+threshold+for+the+biosure+regenesorb+screw+material/pmc11491983-136-5-10
    Average 90 stars, based on 1 article reviews
    hounsfield unit threshold for the biosure regenesorb screw material - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc hamstring tendon autograft with biosure regenesorb interference screw tibial fixation
    The Biosure <t>Regenesorb</t> interference screw with its fenestrated design provides circumferential communication with the tibial tunnel and is composed of an absorbable material consisting of a combination of calcium sulphate (20%), b‐TCP(15%) and PLGA (65%).
    Hamstring Tendon Autograft With Biosure Regenesorb Interference Screw Tibial Fixation, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/hamstring+tendon+autograft+with+biosure+regenesorb+interference+screw+tibial+fixation/pmc11491983-43-19-23
    Average 90 stars, based on 1 article reviews
    hamstring tendon autograft with biosure regenesorb interference screw tibial fixation - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc interference screws biosure pk
    The Biosure <t>Regenesorb</t> interference screw with its fenestrated design provides circumferential communication with the tibial tunnel and is composed of an absorbable material consisting of a combination of calcium sulphate (20%), b‐TCP(15%) and PLGA (65%).
    Interference Screws Biosure Pk, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/interference+screw+biosure/pm38394990-72-25-27
    Average 90 stars, based on 1 article reviews
    interference screws biosure pk - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc biosure® screw fixation
    Femoral fixation techniques. (A) Groups F1, F2, interference fixation with a 5 mm for F1 and a 7 mm screw for F2 <t>(Biosure©</t> RG 5 mm and Biosure© RG 7 mm). (B) Group F3, anchor fixation (Healicoil Regenesorb 4.75 mm Anchor). (C) Group F4, suspensory fixation using an endobutton (Ultrabutton©).
    Biosure® Screw Fixation, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/biosure+pk+screw/pmc10854485-86-34-34
    Average 90 stars, based on 1 article reviews
    biosure® screw fixation - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    90
    Biosure Inc biosure© rg screw
    Femoral fixation techniques. (A) Groups F1, F2, interference fixation with a 5 mm for F1 and a 7 mm screw for F2 <t>(Biosure©</t> RG 5 mm and Biosure© RG 7 mm). (B) Group F3, anchor fixation (Healicoil Regenesorb 4.75 mm Anchor). (C) Group F4, suspensory fixation using an endobutton (Ultrabutton©).
    Biosure© Rg Screw, supplied by Biosure Inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
    https://www.bioz.com/product/screw+biosure/biosure+pk+screw/pmc10854485-16-4-1
    Average 90 stars, based on 1 article reviews
    biosure© rg screw - by Bioz Stars, 2026-10
    90/100 stars
      Buy from Supplier

    Image Search Results


    The Biosure Regenesorb interference screw with its fenestrated design provides circumferential communication with the tibial tunnel and is composed of an absorbable material consisting of a combination of calcium sulphate (20%), b‐TCP(15%) and PLGA (65%).

    Journal: Journal of Experimental Orthopaedics

    Article Title: Resorption characteristics of an open architecture biocomposite interference screw after ACL reconstruction

    doi: 10.1002/jeo2.70016

    Figure Lengend Snippet: The Biosure Regenesorb interference screw with its fenestrated design provides circumferential communication with the tibial tunnel and is composed of an absorbable material consisting of a combination of calcium sulphate (20%), b‐TCP(15%) and PLGA (65%).

    Article Snippet: The CT scanning analyses investigated the development of Biosure Regenesorb screw resorption and the volume of the tibial bone tunnel in which the screw was inserted to fix the soft tissue ACL graft (Table ).

    Techniques:

    Femoral fixation techniques. (A) Groups F1, F2, interference fixation with a 5 mm for F1 and a 7 mm screw for F2 (Biosure© RG 5 mm and Biosure© RG 7 mm). (B) Group F3, anchor fixation (Healicoil Regenesorb 4.75 mm Anchor). (C) Group F4, suspensory fixation using an endobutton (Ultrabutton©).

    Journal: SICOT-J

    Article Title: What is the best fixation method in medial patellofemoral ligament reconstruction? A biomechanical comparison of common methods for femoral graft attachment

    doi: 10.1051/sicotj/2024004

    Figure Lengend Snippet: Femoral fixation techniques. (A) Groups F1, F2, interference fixation with a 5 mm for F1 and a 7 mm screw for F2 (Biosure© RG 5 mm and Biosure© RG 7 mm). (B) Group F3, anchor fixation (Healicoil Regenesorb 4.75 mm Anchor). (C) Group F4, suspensory fixation using an endobutton (Ultrabutton©).

    Article Snippet: Regarding Stiffness at 1000 cycles, mean stiffness was similar in the endobutton and 4.75 mm Healicoil anchor groups (111 ± 21 N/mm and 119 ± 20 N/mm respectively), and lowest in the 7 mm Biosure© screw fixation group (90 ± 5 N/mm).

    Techniques:

    Record of graft failure modes. (A) Suspensory fixation device Ultrabutton© failure by suture breakage. (B) Interference screw Biosure© RG failure by graft slippage. (C) Suture anchor Healicoil Regenesorb 4.75 mm failure by anchor pull-out.

    Journal: SICOT-J

    Article Title: What is the best fixation method in medial patellofemoral ligament reconstruction? A biomechanical comparison of common methods for femoral graft attachment

    doi: 10.1051/sicotj/2024004

    Figure Lengend Snippet: Record of graft failure modes. (A) Suspensory fixation device Ultrabutton© failure by suture breakage. (B) Interference screw Biosure© RG failure by graft slippage. (C) Suture anchor Healicoil Regenesorb 4.75 mm failure by anchor pull-out.

    Article Snippet: Regarding Stiffness at 1000 cycles, mean stiffness was similar in the endobutton and 4.75 mm Healicoil anchor groups (111 ± 21 N/mm and 119 ± 20 N/mm respectively), and lowest in the 7 mm Biosure© screw fixation group (90 ± 5 N/mm).

    Techniques: